Liquid flow measurement of gas density meter CF mass flow sensor imports

Liquid flow font b measurement b font of gas density meter CF mass flow sensor imports
Click to see details
Liquid flow font b measurement b font of gas density meter CF mass flow sensor imports
60 % of buyers enjoyed this product!
Availability: in stock
Price:  $ 14600.00 / piece


Get Access to Great Discount

45 days Money back 45 days Money back Returns accepted if product not as described, buyer pays return shipping; or keep the product & agree refund with seller.
On-time Delivery On-time Delivery
Guarantees: On-time Delivery 60 days

Share:

High PrecisionELI Coriolis Flow and Density Meters

performance

1) EliSeries to the liquid mass flow , volume flow measurement performance and high density , precise, accurate;

2) EliSeries gas mass flow measurement with high performance;

3 )EliSeries have reliable two-phase flow measurement performance;

4 )EliSimple series of operations , easy to install;

applicability

1) Suitable for wide caliber than the installation environment , and : sanitary , low temperature , high temperature and high pressure ;

2) ApplyI / O Products;

reliability

1) Smart Meter Verification can be verified , and a check for the key state of equipment and performance ;

2) A global leader in ISO / I 17025 calibration facilities first-class performance , uncertainty of only ± 0.014%;

3 )Design of Intelligent Sensor reduces the demand for on-site calibration ;

High PrecisionELITE® Series Coriolis Flow and Density Meters

High PrecisionELIFor high-performance series with flow and density measurement , which can provide complex application environments ( such as liquids, gases , slurries , etc. ) of the most reasonable solution.

Reliable performance widely used

1) Large flow pipe size and design flow range , can provide the optimal solution;

2) Self-draining design the best performance , a variety of class certification, to provide a reasonable solution for sanitary spaces;

3 )suitableForguardHealth ,lowmildhighPressure, etc.manySeed shoulduseoccasion.

Standard best choice

1) provideMultipleTransmitters and installation options for each application , the maximum extent compatible with your system;

2) haveAdvanced level , in line with ISO-I 17025 calibration means uncertainty reach ± 0.014%, for optimal measurement accuracy;

3 )haveThe industry’s most communication protocol products:Smart Wireless;

4 )reliableMultivariable can simultaneously measure the necessary flow and density process variables;

5 )Housing rating in line with standard E B31.3 and UR 132.

Advanced Diagnostic Intelligent Tester

1) Comprehensive testing different work environment , excellent manifestation meter The functionality and performance;

2) 90 seconds a comprehensive test instrument performance , the fastest instrument state understand ;

3 )Check to minimize labor costs while eliminating work stoppage;

Controllability accurate detection

1) With low frequency sensors , dramatically reducing the uncertainties caused by gas , thereby ensuring accurate measurement two-phase flow ;

2) Transmitters and high-performance digital signal processing VD (D), to provide the most rapid rate of response for precise batch and two-phase flow measurement ;

3 )Using a gas porosity (GVF) measurement medium . This parameter confrontation volume flow accuracy impact varies with the application .

Measuring principle

As a practical application of the Coriolis effect , the working principle of the Coriolis mass flowmeter is such that there are medium flowing through the flow tube vibration occurrence . Although vibration is not a complete circle , still forming a rotating coordinate system , causing the Coriolis effect . Sensors will detect and analyze changes in flow tube frequency , phase and amplitude . Specific detection methods

Due to the flow meter design varies , but these are observed changes represent a fluid mass flow and density.

Mass Flow MeasurementMeasuring tube to oscillate under the action , resulting in a sine wave. When the flow is zero , two tubes in phase vibration . During flow , the Coriolis force to promote pipeline distorted, causing phase shift . This is the phase difference between the two waveforms and mass flow rate is proportional .

Density measurement

Vibration at the natural frequency of the measuring tube . Changes in the quality of media channels will cause the natural frequency of the pipe changes accordingly . By frequency change conduit to calculate the density .

Temperature Measurement

Temperature as measured variables , can be used as output. In addition, the internal temperature sensor to compensate for the influence of temperature on the elastic modulus in .

Instrument Characteristics

□ Medium mass flow measurement accuracy and operating temperature, pressure or composition irrelevant . However, the sensorPressDrop depends on the operating temperaturedegree,Pressure groups and mediaMinute.

□Specifications and performance vary with different models , some models may have fewer options available . relatedSexCan details and featuresinterest,See.

□ With CF name (CF, CFHC, CFS) All instruments belong ELITE Instrument series ; unless otherwise indicated,Otherwise, the name of the above and other instruments represent ELI

Series of instruments with the same quality and performance.

□ The basic model of the end of the letter (such as CF100)Representative wetted parts materials and / Or application nameCall: = 316L stainlesssteel, L = 304L stainless steel, H = Nickel alloyC22,P = Nickel alloy C22/316L stainless steel,A = high temperature 316L stainless steel,B = High temperature nickel alloys C22,Y = Duplex stainless steel (UNS S32750 ).

( 524,681,188,351 ) ( 113,423,168 )

Average Star Rating:
0 out of 5 (0 Ratings)
Name Rating Feedback
Shipping Company Shipping Cost Estimated Delivery Time
DHL 3 - 7 days
UPS Expedited 3 - 7 days
EMS 5 - 14 days
Post Air Mail Free Shipping 15 - 45 days
Return Policy If the product you receive is not as described or low quality, the seller promises that you may return it before order completion (when you click "Confirm Order Received" or exceed confirmation timeframe) and receive a full refund. The return shipping fee will be paid by you. Or, you can choose to keep the product and agree the refund amount directly with the seller.

N.B.: If the seller provides the "Longer Protection" service on this product, you may ask for refund up to 15 days after order completion.
Seller Service On-time DeliveryIf you do not receive your purchase within 60 days, you can ask for a full refund before order completion (when you click "Confirm Order Received" or exceed confirmation timeframe).
Price:  $ 14600.00 / piece
Get Access to Great Discount
Resource Arena Technology
24/7 Customer Service (800) 927-7671